Off-grid Solar Inverter | 1.2kW–10kW Toroidal transformer | 110V/120V Output Available

  • Pure sine wave output
  • Can support WIFI / GPRS
  • MPPT Efficiency max 98%
  • Optional built-in MPPT/PWM30-60A controller
  • DC Start & Automatic Self-Diagnostic Function
  • Automatically send signal to start generator
  • High efficiency design for optimized battery performance
  • Selectable charging current based on applications
  • lead acid battery/Lithium battery
  • BMS function for lithium battery
  • AC start-up voltage auto restart voltage/110V/120V Output Available
Model VS1512AM VS2024AM VS3024/48AM6 VS5024/48AM6 VS6348AM8 VS8048AM8 VS10048AM8 VS12548AM8
AC Input
AC Input voltage 220VAC(standard)
Input voltage range 154-264VAC±3V(Nor Mode)185-264VAC±3V(UPS mode)
175-285VAC±3V(AVR Type)
Input frequency 50/60Hz±5%
AC Mode Output
Out put power 1500VA
1200W
2000VA
1600W
3000VA
2400W
5000VA
4000W
6300VA
5000W
8000VA
6400W
10000VA
8000W
12500VA
10000W
AC model output Voltage The output voltage under the mains is the same as the input voltage(with AVR function 220V±10%)
Battery Mode Output
Battery model output voltage 220VAC±10%
Battery model output frequency 50HZ or 60HZ±1%
Battery model output wave Pure sine wave
load peak ratio (MAX)3:1
Battery
Battery type External lead-acid battery,Gel battery, water battery or Lithium battery
Battery voltage 12VDC/24VDC/48VDC 48VDC
Battery charging voltage 13.7VDC/27.4VDC/54.8VDC 54.8VDC
PV Input
Maximum PV array power 12V: 800W 24V:1600W 48V:3200W 6400W
Solar input voltage range 12V: MPPT 15V-50VDC
24V: MPPT 30V-150VDC
48V: MPPT 60V-150VDC
48V: MPPT 60V-150VDC
Maximum PV Display Open Circuit Voltage 50VDC 150VDC
Maximum solar charging current 60A 120A
Maximum AC Charge Current 40A 33A 50A/25A 80A/40A 50A 65A 80A 100A
Transfer & Protection
Transfer time ≤10ms(UPS Mode) / ≤20ms(INV Mode)
Protective function Under the mains: input over current fuse
Under inverter: overload protection, short circuit protection, Iow voltage protection. (with battery anti-reverse connection board)
Display & Notification
Status Display You can view parameters such as AC voltage, AC frequency, PV voltage, PV current, output voltage, output frequency, battery voltage, load current and other parameters by turning the page keys.
Voice prompt Low battery protection buzzer long beep Low battery buzzer beeps every second Machine fault buzzer beeps
Overload buzzer beeps
When the overload is less than 130%, the buzzer will sound every second, and the output will be turned off after 30S. When the overload is greater than 150%,the output will be turned off after 300mS.
Environmental
Operating temperature -10℃~50℃
Storage temperature -15℃~45℃
Relative temperature -10℃~90℃ no condensation
Noise <45dB

GET IN TOUCH